Technical data – Fronius Selectiva Plus (three-phase) User Manual

Page 46

Advertising
background image

16

Troubleshooting

(continued)

Technical Data

Technical Data

Mains voltage (+/- 10%)

3 x 400 V AC, 50/60 Hz

Nominal output max.

see charger rating plate

Charging voltage

see charger rating plate

Charging current

see charger rating plate

On-time

100 %

EMC standard

EN 61000-6-4 (Class A)
EN 61000-6-2

Protection *)

IP 21

Operating temperature **)

-10°C to + 50°C

14°F to 122°F

Storage temperature

-25°C to + 80°C

-13°F to 176°F

Mains connection (@PCC) ***)

S

SC min

565

kVA

Z

max

283

m Ohm

Marks of conformity

see charger rating plate

Weight inclusive of mains and charger leads
Selectiva Plus D 7 kW

18.5 kg (40.8 lb)

Selectiva Plus D 14 kW

40 kg (88.20 lb)

Dimensions w x h x d
Selectiva Plus D 7 kW

640 x 280 x 180 mm (25.20 x 11 x 7.10 in.)

Selectiva Plus D 14 kW

625 x 475 x 290 mm (24.60 x 18.70 x 11.41)

ERROR 401 -420

Cause:

Charger faulty

Remedy:

Contact After-Sales Service

NOTE! For indoor use only, do not expose the charger to rain or snow

*)

**) at higher temperatures a drop in performance may occur (derating)

***) valid for Selectiva D 8140/8120/8100