Fulgor Milano CPH 401 ID X User Manual

Page 25

Advertising
background image

24

25

GB

Error code

description

Possible causes

Error recovery

E/A

Hardware defect of
induction modul.

Defect hardware device
detected by the self
check of the modul.

Exchange the modul.

E/C

Configuration failure.

2 cooking zone are
dedicated to the same
element of the UI.

1. Erase the actual
configuration manual with
service menù.

E/H

Fixed sensor value (test
function for T sensor on
inductor).

Not enough
temperature change
(10K) within 5 min after
switch on the hob.

Systerm must cool down.

No functionality
and no
displaying

Overvoltage on the switch
mode power supply (jno
fuctionality).

400V connection.

Disconnet and correct the
power line connection.

E

A blinking “E” on each
cooking zone indicates, that
all configs will be.

The user is in the
service menù, it’s not
an error.

Manual configuration.

E/2
(Error code
different for
some UI)

Temperature limits are
excessed.

1. Pot or glas
temperature is to
2. NTC - electronik
temperature to high.

System must cool down.

E/3

Unsustable pot, e.g. lost of
the magnetic characteristics
because of temperature in
the bottom.

Pot creates on the
modul an improper
operating point which
can destroy devices,
e.g. IGBT.

1. the error is automaticly
cancelled after 8s and
the cooking zone can be
used again. In case of
further upcoming errors
the post have to be
changed.
2. the modul has to be
changed if the error
comes without an pot on
the cooking zone.

E/4

Unconfigured induction
modul (all induction modul
answer to UI, but any
element is related to the
effected cooking zone).

Induction modul is not
configured.

1. Delet the hob
configuration and activate
the manual configuration.
2. Start the UI service
menue to configure the
imduction modul.
3. If the listed points are
not succesful replace the
modul.

E/5

No communication between
UI and inducation modul.

No power supply of
induction modul
Mal cabeling or defect
of.

Check power and lin
connections is the
connention ok, replace
the modul.

E/6

Main power disturbace .

1. Failure in main power
frequency detection.

Check main power
voltage and frequency,
if ok.