Model 263-000 Isolation Barrier Unit

Electrical /Acoustical

Telephone Network Interface.................. (2-wire) ........................................ BELL Pub. 61100 Compatible

(4-wire) .................................................. See 4-wire option below

AC power input ....................................... Voltage (selectable) ...................................................... 90–132 V

180–240

V

Frequency

........................................................................................................................... 47–63 Hz

Current ............................................................................................................ 0.5 amps (maximum)

Ringer pitch adjust ........................................................................................................... 1–8 kHz (nominal)
Intrinsically safe Interface
Voltage

(maximum) ............................................................................................................. 18 volts

Resistance

(minimum) ......................................................................................................... 66 ohms

Current

limited

(maximum) ................................................................................................. 136 mA

Indicators

I.S. Loop Current .............................................................................................................. I.S. LOOP (GRN)
I.S. Lock Detect ................................................................................................................ I.S. LOCK (GRN)
Telephone line loop current ................................................................................................... TELCO (YEL)
Hook ........................................................................................................................................ HOOK (YEL)

Mechanical

Housing construction ........................................................................................... Glass-reinforced polyester
Housing dimensions ................................. 9.39 W

 13.16 H  7.46 D inches; (238.5  334.3  189.5 mm)

Enclosure rating ............................................................................................................. Type 3R (rainproof)
Weight ............................................................................................................................... 8.5 lbs. (3.86 kg)

4-Wire Option - Model 263-000 IBU Interface Specifications

Receive (TB2-1, 2) ...................................................................................................................... Dry (No dc)

Signal level ............................................................................................................ 0 dBm (nominal)

+3 dBm (maximum

Transmit (TB2-3, 4) ..................................................................................................................................Wet

DC loop current ............................................................................................................... 20–70 mA

Signal level ............................................................................................................ 0 dBm (nominal)

Ring voltage input ....................................................................................................... 40–150 Vrms