Maintenance

This section includes two troubleshooting charts designed to quickly pinpoint the source of problems.

Troubleshooting

N

OTE

: It may be advantageous to temporarily connect a Model 262-001 or 272-001 Telephone panel

directly to the output terminals of the Model 263-000 IBU when troubleshooting. Then, using the charts
below, the cause of the problem should more easily be determined.

Non-Equipment Related Problems

Problem Solution

The I.S. telephone is inactive
with no lights on the IBU when
the telephone is off-hook.

1. Check the ac power to the Model 263-000 IBU.

2. Check the ac fuse F4 at the Model 263-000 IBU.

3. Ensure there is no wiring open at the I.S. telephone.

The I.S. telephone has no dial
tone.

1. If the I.S. telephone has a wiring short, the IBU lights will be lit

in the following pattern:

 =

On

,

= Off

ISLOOP

LOCK

HOOK

TELCO

2. If the TELCO line has an open, the IBU lights will be lit in the

following pattern:

 =

On

,

= Off

ISLOOP

LOCK

HOOK

TELCO

The lights on the IBU flash
randomly.

The I.S. telephone has an intermittent wiring short. The short may be
between the conductors or either/both conductor(s) to ground/shield.