Recommended cabling, Voip telephone input contacts, Voip telephone output contacts – GAI-Tronics 393-700 RED ALERT 300 Series Hands-free VoIP Telephone Manual User Manual

Page 19: Status indication, Power, Heartbeat, Eact

Advertising
background image

P

UB

.

42004-441G

H

ANDS

-

FREE

V

O

IP

T

ELEPHONES

P

AGE

17 of 24

e:\standard ioms - current release\42004 instr. manuals\42004-441g.doc
02/15

Recommended Cabling

Table 5. Recommended Cabling

Cable Use

Size and Type

Power

Two-conductor, No. 22 AWG is typical

Inputs

Two-conductor, No. 22 AWG is typical

Output contacts

Two-conductor, No. 18 AWG is typical

Antenna RG58

coaxial

cable

VoIP Telephone Input Contacts

Each RED ALERT

®

VoIP Telephone accepts four inputs. Refer to the “Specifications” section of this

manual for the input ratings.

The function of each input is configurable. Inputs can be configured for one of the following modes: On,
Off, or On/Off. The signals can also be inverted between active high (INVERT) or active low
(NORMAL). Activation of these inputs can be configured to update a SYSLOG or generate an email.
Please refer to Figure 16 on page 15 of this manual and the “Logic Settings” section of GTC Pub. 42004-
396, “VoIP Telephone Configuration Guide” for programming instructions for these inputs.

VoIP Telephone Output Contacts

Each RED ALERT

®

VoIP Telephone contains two volt-free output contacts. Refer to the

“Specifications” section of this manual for the output ratings. Both outputs are single-pole, single-throw
contacts.

The function of each output is configurable. Outputs can be configured for one of the following modes:
On, Off, Pulse, Mute, Ring, Call, Connect, Hook, In Use, Ring Cadence, Ring Out, Page, Registered, or
Emergency. In some modes, the duration of the activation or on/off times can also be set. Please refer to
Figure 16 on page 15 of this manual and the “Logic Settings” section of GTC Pub. 42004-396, “VoIP
Telephone Configuration Guide” for programming instructions for these outputs.

Status Indication

Power

The Power LED located on the VoIP PCBA illuminates when power is applied to the telephone. Refer to
Figure 16 on page 15 for location.

Heartbeat

The Heartbeat LED located on the VoIP PCBA will flash once communication over the LAN is
established. Refer to Figure 16 on page 15 for location.

EACT

The EACT LED located on the VoIP PCBA will turn ON when VoIP PCBA is connected to an Ethernet
device and flash when data is being transmitted. Refer to Figure 16 on page 15 for location.

Advertising