TB4 - Audio and Low Voltage Control Terminal Block

The following is a list of connections for the low voltage control and audio signal terminal block, TB4:

Name Pin

No.

Description

Aux Mic+

1

Positive terminal for auxiliary microphone (optional).

Aux Mic−

2

Negative terminal for auxiliary microphone (optional).

Ext Cont+

3

Talk/listen control signal for Master/Slave operation.
No connection in Common Line mode.

Ext Cont−

4

Ground reference for talk/listen control signal for Master/Slave operation.
No connection in Common Line mode or UNBAL audio configuration.

Shield

5

Ground reference for shield terminations.

Audio+

6

Positive of the audio line during 600-ohm or 15-kilohm termination
configuration.

Audio−

7

Negative of the audio page line during 600-ohm or 15-kilohm termination
configuration.

Footswitch+

8

Positive of optional auxiliary footswitch operating as local push-to-talk switch.

Footswitch−

9

Negative of optional auxiliary footswitch that operating as local push-to-talk
switch.