P3 - balanced / unbalanced jumper, Sw1 - master/slave switch – GAI-Tronics 400-003 IEC / ATEX Zone 1 RigCom Station User Manual

Page 11

Advertising
background image

Pub. 42004-460A

Model 400-003 IEC/ATEX Zone 1 RigCom Station

Page: 11 of 16

f:\standard ioms - current release\42004 instr. manuals\42004-460a.doc
09/12

P3 - Balanced / Unbalanced Jumper

Jumper P3 allows the installer to configure the unit for balanced or unbalanced audio connections. If the
header is installed in the BAL position, the assembly is configured for a balanced audio input signal
operation. If the header is installed in the UNBAL position, the assembly is configured for an unbalanced
input signal. In systems where the external control signal is single-ended, the system must be set up as an
unbalanced system.

SW1 - Master/Slave Switch

Switch SW1 allows the installer to configure the unit as a Slave or Master unit. If the switch is in the
SLAVE

position, the unit is configured as a Slave. If the switch is in the MASTER position, the unit is

configured as a Master. For Common Line operation, the switch must be in the MASTER position.

Figure 9. RigCom Station PCBA

Advertising