GAI-Tronics 780-301 Page/Party Handset Station (Cenelec Zone 1) User Manual

Page 11

Advertising
background image

Pub. 42004-638L2

Model 780/7805-301 Page/Party

®

Handset Stations for Cenelec Zone 1 Applications

Page: 11 of 15

\\s_eng\gtcproddocs\standard ioms - current release\42004 instr. manuals\42004-638l2.doc
6/98

To make these adjustments, remove the assembly from its enclosure and make a temporary connection
between the assembly and the enclosure as described in the following steps:

1. Loosen the four captive screws that secure the front panel.

2. Remove the assembly from the enclosure.

3. Connect the assembly to the enclosure using a Model 10440-002 Maintenance Cable between P1 on

the assembly and J1 on the enclosure.

4. Locate the control on the appropriate PCBA. Using a small flat-blade screwdriver with an insulated

shaft, turn a control clockwise to increase the volume or threshold; turn it counterclockwise to
decrease the volume or threshold.

5. When you are done with the adjustment:

a) Disconnect the Model 10440-002 Maintenance Cable.

b) Insert the assembly into the enclosure.

c) Tighten the four screws.