Control Tones

Standard EIA tone keying tones are used for controlling the radio system. The sequence is:
 A 2175 Hz High Level Guard Tone (HLGT) for 120 ms.
 One of 16 function tones (FT) is sent for 40 ms.

FTs range from 2050 Hz to 550 Hz in 100 Hz steps. The FT level is 10 dB lower than the HLGT.

Monitor

2050

FT4

1650

FT8

1250

FT12

850

FT1

1950

FT5

1550

FT9

1150

FT13

750

FT2

1850

FT6

1450

FT10

1050

FT14

650

FT3

1750

FT7

1350

FT11

950

FT15

550

 A 2175 Hz Low Level Guard Tone (LLGT) is generated for the duration of the transmission. The

LLGT is not generated during monitor. Because voice is present with this LLGT, a 2175 Hz filtering
is required in the tone panel.

When the monitor (CTCSS disable) is activated, the HLGT is generated for 120 ms, then a function tone
of 2050 Hz is generated for 40 ms.

Tone Levels

Assuming that the ITR2000A has the HLGT output level set to 0 dBm:

 The FT level and audio voice level are –10 dBm (10 dB below HLGT)
 The LLGT level is –30 dBm.
 The HLGT and FT durations are programmable.

Some tone panels use the value of the FT frequency to provide certain radio control functions. If the
radio supports channel changes from an external logic source, the FT1 frequency of 1950 Hz could be
used to change the radio to channel 1. An FT6 frequency of 1450 Hz could change the radio to
channel 6.

Accessories

Description Part

No.

GAI-Tronics Programming Bundle CD

XAC4000A

Desk Microphone

XDM004A

Footswitch (requires XAAB002A) XFS002A

Gooseneck Microphone

XGM002A

Amplified Headset, Single Earpiece (requires coiled cord)

XHS003C

Coiled Cord for XHS003C (requires XAAB002A)

XCC004B

Coiled Cord with PTT for XHS003C (requires XAAB002A)

XCC003C