High level guard tone durations, Function tone durations – GAI-Tronics ITR1000-001 Model ITR1000-001 Basic Tone Remote Deskset with Line Select User and Installation Manual User Manual

Page 22

Advertising
background image

Installation

ITR1000-001 Basic Tone Remote Desk Set

02/12 18

High Level Guard Tone Durations

F1 F2 F3 F4

Duration

Off Off Off Off

120

ms

Off Off Off On

200

ms

Off Off On Off

300

ms

Off Off On On

400

ms

Off On Off Off

500

ms

Function Tone Durations

F1 F2 F3 F4

Duration

Off Off Off Off 40

ms

Off Off Off On 50

ms

Off Off On Off

60

ms

Off Off On On 70

ms

Off On Off Off

80

ms