Belt Drive Duct Fan

1

®

®

Document 458341

Model BDF

Belt Drive Duct Fan

Model BDF Belt Drive Duct Fan

Model BDF is a belt drive duct supply, exhaust or return air fan. These
fans are specifically designed for inline applications. Performance
capabilities range up to 15,000 cfm (25,500 m

3

/hr) and up to 3.0 in. wg

(747 Pa) of static pressure. BDF fans are available in seven sizes with
nominal wheel diameter ranging from 8 to 20 inches (203 to 508 mm)
(080 - 200 unit sizes). Each fan shall bear a permanently affixed
manufacture’s engraved metal nameplate containing the model number
and individual serial number.

General Safety Information

Only qualified personnel should install this fan.
Personnel should have a clear understanding of these
instructions and should be aware of general safety
precautions. Improper installation can result in electric
shock, possible injury due to coming in contact with
moving parts, as well as other potential hazards. Other
considerations may be required if seismic activity
is present. If more information is needed, contact a
licensed professional engineer before moving forward.

1. Follow all local electrical and safety codes, as well as

the National Electrical Code (NEC) and the National
Fire Protection Agency (NFPA), where applicable.
Follow the Canadian Electric Code (CEC) in Canada.

2. The rotation of the wheel is critical. It must be free

to rotate without striking or rubbing any stationary
objects.

3. Motor must be securely and adequately grounded.

4. Do not spin fan wheel faster than max cataloged fan

RPM. Adjustments to fan speed significantly effects
motor load. If the fan RPM is changed, the motor
current should be checked to make sure it is not
exceeding the motor nameplate amps.

5. Do not allow the power cable to kink or come in

contact with oil, grease, hot surfaces or chemicals.
Replace cord immediately if damaged.

6. Verify that the power source is compatible with the

equipment.

7. Never open access doors to a duct while the fan is

running.

DANGER

Always disconnect, lock and tag power source before
installing or servicing. Failure to disconnect power
source can result in fire, shock or serious injury.

CAUTION

When servicing the fan, motor may be hot enough
to cause pain or injury. Allow motor to cool before
servicing.

CAUTION

Precaution should be taken in explosive atmospheres.

DANGER

Pour écarter les risques d’incendie, de choc électrique
ou de blessure grave, veiller à toujours débrancher,
verrouiller et étiqueter la source de courant avant
l’installation ou l’entretien.

ATTENTION

Lors de toute intervention sur la soufflante, le moteur
peut être suffisamment chaud pour provoquer une
douleur voire une blessure. Laisser le moteur refroidir
avant toute maintenance.

ATTENTION

Faire preuve de précaution dans les atmosphères
explosives.