Harken 7311.10 Cruising Jib Reefing & Furling User Manual

Page 21

Advertising
background image

Commissioning

Lead Line to Cockpit

08/23/10

Unit 1, 2 Cruising

21

Run line through enclosed window in guard and into

hole in bottom plate of spool. Tie a small overhand

knot and pull it up under drum assembly.

Mount Lead Blocks

Furling line can be led down either side of boat. If boat is in slip, consider mounting opposite dock.
Remove four screws on stanchion blocks. Clamp blocks to stanchions. See instructions below.
Tip: Start all four screws before tightening.

7403

OUTBOARD

STANCHION

BLOCK

7403

OUTBOARD

STANCHION

BLOCK

7402

RATCHET

STANCHION

BLOCK

STERN

BOW

7401

FORWARD

STANCHION

BLOCK

7403

OUTBOARD

STANCHION

BLOCK

Note location of sun cover. Charge system by rotating furler to wrap line on drum.
Tip: Sun cover to starboard—turn clockwise to charge. Sun cover to port—turn counter-clockwise. Tension line

while charging.

Enclosed

Window

Note: As furling line lead changes, make sure line

doesn’t chafe against line guard. Rotate line guard

if necessary.

Drum Empty

(sail furled)

Drum Full

(sail unfurled)

Position 7401 Forward Stanchion Block so line

enters drum at right angles to headstay and centers

vertically in opening. Install so line is inside stanchion.

Correct block position is critical to even

line spooling and ease of furling.

7401 Forward Stanchion Block

Install 7403 Outboard Stanchion Blocks so line is

outside stanchions.
Number and placement of leads depends on boat

length and number/configuration of stanchions.

7403 Outboard Stanchion Blocks

Mount 7402 Ratchet Stanchion Block as furthest-aft

lead to prevent line overrides in drum when unfurling.

Position ratchet block so line turns at least 90°.
Install so line is inside stanchion.
Lead line through block so ratchet makes

clicking sound when pulling line to furl sail.
Tip: Make sure ratchet switch is in “ON” position. If there is

no clicking sound, lead line through block in opposite direction.
Lead line to Furling Line Cleat in cockpit.

7402 Ratchet Stanchion Block

Install so line is angled as shown.

Use #10 (5 mm) fasteners.

HCP168 Furling Line Cleat

WARNING! If line is led through opening

between two enclosed windows it can ride

above lineguard and jam furler. This can

cause an accident, damage to your vessel,

personal injury, or death. See www.harken.

com for additional safety information.

Advertising