Single channel interface box installation -7, Controller cable connector information -7, Connect cables -7 – Hypertherm LH2100 User Manual

Page 22: Single-channel interface box installation -7, Single-channel interface box installation

Advertising
background image

single-channel interface box installation

The single-channel interface box provides 3 independent optically isolated outputs. Outputs can be used by the
controller to detect piercing and cutting operations.

Controller cable connector information (9 pin D-Sub)

J1 pin-outs (Output To Controller)

Output Circuit

+ Output

+ Output

MOC8050

I

f

= 2mA

Connect cables

Controller cable – 9 pin cable to controller

Sensor cable – interface box to laser head

Pin

Wire

Number

Color

Description

1

Red

Voltage in+ (9-36 VDC, 2 watts maximum)

2

Black

Voltage in-

3

White

Cut error +

4

Green

Cut error -

5

Blue

Continuous wave pierce complete +

6

Brown

Continuous wave Pierce complete -

7

Orange

Pulsed pierce complete +

8

Yellow

Pulsed pierce complete -

9

Shield

Electromagnetic protection (earth ground)

1

INSTALLATION

LH2125/LH2100 Laser Head Instruction Manual

3-7

Note: Nominal voltage drop across output (+/-) is 1.2 volts. Current must be limited by input

resistance.

Advertising
This manual is related to the following products: