Hypertherm LH2100 User Manual

Page 44

Advertising
background image

0

OPERATION

LH2125/LH2100 Laser Head Instruction Manual

4-17

Is dross hard &

shiny?

Is dross brittle

& pourus?

Are parameters set to stated

specifications or to a process

used in the past?

Yes

No

No

Yes

Increase oxygen pressure.

Have you cut this

material before?

Yes

No

Set to closest available process parameters.

Yes

No

Decrease cutting

speed.

Yes

No

Increase nozzle

diameter.

No

Check lens for dirt
or damage.
Clean or replace.

Yes

No

Yes

Other possible causes:

– Oxygen purity

– Low grade material

– Laser mode
– Focal position

Decrease oxygen pressure.

Yes

No

Adjust focal position.

Yes

No

Decrease nozzle diameter.

No

Check lens for dirt or damage.
Clean or replace.

Yes

No

Yes

Other possible causes:

Yes

No

Yes

Is problem corrected?

Not a known

dross problem

Record new settings

and continue cutting.

Is problem corrected?

Is problem corrected?

No

Is problem corrected?

Is problem corrected?

Is problem corrected?

Is problem corrected?

Is problem corrected?

Is problem corrected?

Yes

Dross on mild steel

Correct the parameters for pressure,
assist-gas type, focal position, focal length,
cut speed, nozzle size, nozzle-to-workpiece
height and laser power

Inspect nozzle for damage to baffle,
dross adhesion, beam centering
and orifice condition.
Replace if damaged.

– Oxygen purity

– Low-grade material

– Laser mode