Capacitive height sensing -7, Introduction -7, Capacitive height sensing – Hypertherm LH2100 User Manual

Page 34: Introduction

Advertising
background image

1

OPERATION

LH2125/LH2100 Laser Head Instruction Manual

4-7

Capacitive height sensing

Introduction

The capacitive height sensor measures the relative capacitance between the cutting head nozzle and the work piece.
The lower part of the cutting head is electronically excited and acts as a guard against any stray capacitance from other
sources including the moving components in the cutting head. The signal to the nozzle is carried by the center
conductor of the internal coaxial cable. The signal to the lower part of the cutting head is carried on the shield of the
internal coaxial cable.

Note:

It is important that the lower part of the cutting head is not shorted to ground, and that there is
electrical isolation between the nozzle and the lower part of the cutting head. Isolation is
provided by the insulating washer and a ceramic coating on the top side of the nozzle adapter
and prevents a false tip-touch error signal.

Lower part of the cutting head

If a false tip-touch error is suspected:
Remove nozzle and retaining ring. Inspect for particles between parts, damage and cleanliness. Replace as necessary.

Nozzle

Retaining nut

Insulating washer

Nozzle adapter

Shown with spatter shield and spatter shield retaining nut

Retaining nut wrench (104222)

Retaining nut wrench (104223)

Spatter shield

Spatter shield
retaining nut