Specifications – power supply -2, Powermax1650, Specifications – power supply – Hypertherm Powermax1650 Service Manual User Manual

Page 21

Advertising
background image

Rated Open Circuit Voltage (U

0

)

300 VDC

Output Characteristic*

Drooping

*Defined as a plot of output voltage
versus output current

Rated Output Current (I

2

)

30A – 100A

Hypertherm Standard Rated Output

160 VDC

Voltage (U

2

)

Duty Cycle (X*) at 104°F (40°C) at

U

1

– Volts AC rms

X

rated conditions (U

1

, I

1

, U

2

, I

2

)

200-208 VAC 3PH

60%

230-240 VAC 3PH

70%

*X = T

on

/T

base

,

380-415 VAC 3PH

80%

T

on

= time, minutes

480 VAC 3PH

80%

T

base

= 10 minutes

600 VAC 3PH

80%

Operating temperature

14

o

to 104

o

F (-10

o

to 40

o

C)

Rated AC phases (PH) and line frequency (Hz)

PH

Hz

Standard and CE Model

3

50-60

Rated Input Voltage (U

1

), rated Input

U

1

– Volts AC rms

I

1

-Amps rms

I

1

eff

Current (I

1

) and I

1

eff* at rated Output

200-208 VAC 3PH

53

41

U

2

and I

2

– cutting only.

230-240 VAC 3PH

46

38

380-415 VAC 3PH

27

24

*I

1

eff = (I

1

) X used to determine

480 VAC 3PH

22

20

rating of power cord.

600 VAC 3PH

21

19

U

1

– Volts AC rms

Harmonic

Displacement

Power Factor

Power Factor

Power Factor

200-208 VAC 3PH

0.94

0.98

230-240 VAC 3PH

0.94

0.98

380-415 VAC 3PH

0.94

0.99

480 VAC 3PH

0.94

0.99

600 VAC 3PH

0.78

0.99

R

sce

– Short Circuit Ratio—CE Model only

U

1

– Volts AC rms, 3PH

R

sce

400 VAC

191

230 VAC

142

This equipment conforms to IEC 61000-3-12,

provided that R

sce min

= 191 at 400VAC 3PH

and 142 at 230 VAC 3PH.

IP code—Degree of protection

IP23CS*

provided by enclosure

IP – “International Protection”
2 – No ingress foreign objects

>

=12.5mm (0.5 in)

3 – No harmful ingress spraying water
C – AC line circuits protected against ingress of

tool

>

=2.5 mm dia. x 100 mm long

(0.1 inch x 4.0 inch)

S – fan stationary during water test

*WARNING: DO NOT OPERATE IN RAIN

Toppling, Tilting (with or without wheel kit)

Up to 15

o

incline

.

Gas Type

Air

Nitrogen

Gas Quality

Clean, moisture-free, oil-free

Gas Inlet Pressure and Flow

90-120 psig (6.2-8.3 bar) 550 scfh/9.2 scfm (260 l/min)

2-2

powermax1650

Service Manual

SPECIFICATIONS

0

Specifications – Power Supply

Advertising