Timing diagrams -2, Powermax1650, Service manual – Hypertherm Powermax1650 Service Manual User Manual

Page 71: Normal mode

Advertising
background image

6-2

powermax1650

Service Manual

0

Torch Lead

Length(feet)

50

50

tdelay

(msec)

Time Constant

(msec)

250

1. 200ms DELAY IS FOR TORCH LEAD

PRESSURIZATION.

2. CURRENT (I) VALUES SHOWN FOR 100A UNIT.

t=0

1

0

Start

t

Start

0

1

2ms

Debounced

Arc

0

Pilot

1

2ms

Digitized
XFR signal

Enable

Inverter

0

1

3ms

(INV_EN)

Icommand

0

30A

3ms

Setpoint

10

0

21.5

13ms

Ipilot

(Amps)

Gas

0

1

Postflow

60

Pcritical(15)

at Torch

(psi)

Gas Pressure

Time

x

Consumable

Re-Seat

0

225

Voltage

Arc

(volts)

~

~ 10ms

typ

250

1.6

30

I Setpoint

0

(amps)

I Work Lead

30.0sec

NORMAL MODE

1ms

30

160

210

0.4

21.5A

valid

3ms

tdelay

0

1

If >5.0 sec

pilot arc time out

XFR signal

Digitized

in DSP and

Switch

Constant

Machine Motion

13ms

2.17A/ms

2.17A/ms

>200 ms

1.

013353

ELEC SCHEM:100A TMG

1 OF 2

A