Resistance Check #3

• Troubleshoot illuminated Torch Stuck Open LED on control board PCB3.

1.

Check resistance between Q15 and J17. The value should be < 1

.

If not, check torch leads, torch head, and consumables.

2.

Check resistance between Q15 and J17 with system in Gas Test mode. The value should be > 1 M

.

If not, verify electrode and torch plunger move freely.

3.

Pilot arc shorted – check resistance between Q15 and J17 with torch removed. If value is < 1 K

replace Pilot

Arc IGBT.

4.

Pilot arc open – use a jumper wire to jump J14 to Q15. Then attempt to fire the torch. If the torch fires replace
the Pilot Arc IGBT.

Note: All values are ±15%.