SPECIFICATIONS

powermax1650

Service Manual

2-3

0

Standard Model

Input Voltage

200-208

230-240

400

480

600

Input Current at 16kw Output

53

46

27

22

21

Input Current during Arc
Stretch

75

72

42

34

33

Recommended Fuse

80

80

50

40

40

CE Model

Input Voltage

230

400

Input Current at 16kw Output

46

27

Input Current during Arc
Stretch

72

42

Recommended Fuse

80

50

Three Phase

Three Phase

Power Connection

The Powermax1650 is a universal power supply that configures itself to operate with AC voltages from 200 to 600
3PH (230-400 3PH for CE model). Use a line disconnect switch for each power supply so that the operator can turn
off the power supply quickly in an emergency. Locate the switch so it is easily accessible to the operator. The
interrupt level of the switch must be equal to or exceed the continuous rating of the fuses. Use slow-blow fuses
rated per local and national electrical codes.

Engine Drives

When using an engine drive to power the Powermax1650:

• The engine drive must be dedicated to powering the plasma cutting system.
• Engine drive operation:

1. Set the engine drive output to 3 phase AC.
2. Plug the Powermax1650 power cord into the power outlet.
3. Set the engine drive to the maximum output (see table below).

• Use unshielded consumables if you experience difficulty cutting thicker material (non-CE systems only).

Standard Unit
3 Phase, 50/60 hz, 200 – 600 VAC (480 VAC recommended for best performance)

CE Unit
3 Phase, 50/60 hz, 230 – 400 VAC (400 VAC recommended for best performance)

Engine Drive Rating

PMX1650 Output Current

Performance

30 kw

100 A

Full Arc Stretch

22.5 kw

100 A

Limited Arc Stretch

75 A

Full Arc Stretch

15 kw

75 A

Limited Arc Stretch

50 A

Full Arc Stretch

Advertising