Input

Phase

Input

Recommended Power Cord Gauge Size (mm

2

)

Voltage

Current (I

1eff

)

< 3 m

3 – 7.5 m

7.5 – 15 m

15 – 30 m

30 – 45 m

200 VAC

1

40A

10

10

16

25

25

230 VAC

1

35A

6

6

10

16

25

400 VAC

1

23A

4

4

4

6

10

200 VAC

3

23A

4

4

6

16

25

230 VAC

3

21A

2.5

4

6

10

16

400 VAC

3

13A

2.5

2.5

2.5

4

6

Power Cord Plugs

All 208/240/480V power supplies are shipped with a single-phase power cord and plug. To operate as a three-
phase unit, the user must obtain a power cord and plug that is certified by national or local electrical codes. The plug
should be connected to the power cord by a licensed electrician.

All 200/230/400V and 400V CE power supplies are shipped with a three-phase power cord and no plug. The
user must obtain a plug that is certified by national or local electrical codes. The plug should be connected to the
power cord by a licensed electrician.

Power Cords

If the power cord needs to be changed, use the tables below to choose the proper wire size for the appropriate length
cord. Note that the input current used to determine the cord size is I

1eff

. In the U.S., use a 3-conductor SO type cord

for single-phase, and a 4-conductor SO type cord for three-phase power supplies. In other countries, use cords that
are certified by national or local codes. Prepare the power cord wires as shown in Fig. 2-5 for non-CE power
supplies, or Fig. 2-6 for CE power supplies. Note that all 4 wires must loop through the toroid in the CE power supply.
Cap or tin the conductor leads and use a #10 terminal on the ground wire. The cord should be installed only by a
licensed electrician.

208/240/480/600V Power Supplies

Input

Phase

Input

Recommended Power Cord Gauge Size (AWG)

Voltage

Current (I

1eff

)

< 10 ft

10 – 25 ft

25 – 50 ft

50 – 100 ft

100 – 150 ft

208 VAC

1

39A

8

8

6

4

4

240 VAC

1

33A

8

8

8

6

4

480 VAC

1

19A

12

12

12

10

8

208 VAC

3

23A

8

8

8

6

4

240 VAC

3

20A

10

10

10

8

6

480 VAC

3

10A

12

12

12

12

10

600 VAC

3

8A

12

12

12

12

10

S MARK

The Powermax900 conforms to standard EN50192. The S mark indicates that the power supply and