Service manual, Aintenance – Hypertherm Powermax900 Service Manual User Manual

Page 52

Advertising
background image

3-25

M

AINTENANCE

Service Manual

Figure 3-16 Control Board LED Locations

J8

J1

J3

J4

J7

J6

J5

TP5 (Gnd)

J2

LED3

LED1

LED4

R1

LED2

LED5

LED6

LED7
LED8
LED9
LED10

LED11
LED12
LED13

LED14

S1

9-99

The control board also controls the sequence required to generate plasma:

•

Turns on the inverter approximately 1 second after the torch trigger switch is pressed

•

After a short delay, turns on the gas solenoid valve V1 to blow back the electrode

•

Monitors the pilot arc for arc transfer

•

Ramps the current control command from the pilot arc level (22 amps) to the cut current selected by the
operator

•

Turns the inverter off if the output current fails for any reason

•

Turns the inverter off if the torch blow back does not occur within 2 seconds

•

Turns off the power supply when the retaining cap is loose or when line voltage is too high.

•

LED6 PLASMA START: Illuminates when the torch start button is pushed or when start
button is activated from the machine interface.

•

LED7 INVERTER ON: Illuminates when the command to turn on the inverter modulator is
given.

•

LED8 CURRENT: Illuminates when current greater than 10 amps is detected in electrode
circuit.

•

LED9 BLOWBACK: Illuminates when more than 25 arc volts is detected.

•

LED10 ARC TRANSFER: Illuminates when arc transfers to the workpiece (when arc current
is greater than 1.5 amps).

•

LED12 OVERCURRENT: Illuminates when CS1 or CS2 senses current above 70 amps.
Release the START switch to clear.

•

LED13 FAULT: Illuminates when there is either an overvoltage condition, an imbalance in the
inverters, or a micro-controller failure.