Service manual, Aintenance – Hypertherm Powermax900 Service Manual User Manual

Page 45

Advertising
background image

M

AINTENANCE

3-18

Service Manual

Before switching on the power supply, perform

Visual Checks - Internal, Resistance Checks and also

review the warnings on page 3-9.

Verify that the torch is plugged into the power supply.

Connect the power cord into the line voltage disconnect switch box or plug into a properly
grounded outlet.

Switch the power supply on.

Connect the gas supply to the pressure regulator at the rear of the power supply.

Voltage Check #1 - Figure 3-11

Voltage at Input of Input Diode Bridge
The AC voltage between any 2 input wires will equal the line voltage on 3

φ systems.

On 1

φ systems, the AC voltage between the top 2 input wires will equal the line voltage.

Voltage Checks

SHOCK HAZARD - See warnings on page 3-9
before proceeding.

= Line Voltage

= Line Voltage

= Line Voltage

8 or 32

12

11

3

φ 1φ

Figure 3-11 Voltage Check #1 - Input of Input Diode Bridge