Service manual, Aintenance – Hypertherm Powermax900 Service Manual User Manual
Page 46

3-19
M
AINTENANCE
Service Manual
Voltage Check #2 - Figure 3-12
•
Voltage at Output of Input Diode Bridge
This DC voltage will approximately equal the line voltage X 1.414 - See table below.
Line Voltage
Output at Bridge
200VAC
≈ 280VDC
208VAC
≈ 290VDC
230VAC
≈ 320VDC
240VAC
≈ 340VDC
400VAC
≈ 560VDC
480VAC
≈ 680VDC
≈ Line Voltage
X 1.414
See Table
14
13
Figure 3-12 Voltage Check #2 - Output of Input Diode Bridge
Voltage Check #3 - Figure 3-13
•
Voltage Across Power Board Capacitors (taken at Q1 and Q2)
See the table in Figure 3-13 to find the correct voltage readings across the power board
capacitors.
Figure 3-13 Voltage Check #3 - Across Power Board Capacitors
Line Voltage
Voltage across Wires
21&22 and 15&16
200VAC
≈ 280VDC
208VAC
≈ 290VDC
230VAC
≈ 320VDC
240VAC
≈ 340VDC
400VAC
≈ 280VDC
480VAC
≈ 340VDC
Q1
21
22
See Table
Q2
15
16
See Table