Service manual, Aintenance – Hypertherm Powermax900 Service Manual User Manual

Page 39

Advertising
background image

M

AINTENANCE

3-12

Service Manual

If no problems were found during the initial resistance checks and the power supply still does not
operate correctly, follow the

Troubleshooting Guide.

Note: In the

Troubleshooting Guide are "best-guess" solutions. Study the system wiring diagram and

understand the theory of operation before troubleshooting. Before purchasing a major replacement
component, check with Hypertherm's Technical Service group at 1 800 643 9878 or the nearest
Hypertherm repair facility.

Resistance Check #3 - Fig. 3-10

Across Output DIode Bridge
Take 2 output diode bridge measurements.
First, place the + multimeter lead on wire 29 and the – multimeter lead on wire 30.
Next, place the – multimeter lead on wire 29 and the + multimeter lead on wire 30.
Values are shown below.

3.5K

1.7K

29

+

29

30

30

+

Figure 3-10 Resistance Check #3 - Across Output Diode Bridge

Advertising