400v ce, Service manual, Power supply - 400v ce – Hypertherm Powermax900 Service Manual User Manual

Page 89: Arts

Advertising
background image

6-8

Service Manual

P

ARTS

L

IST

- 400V CE

POWER SUPPLY - 400V CE

Rear

Index No.

Part No.

Description

Ref. Desig.

Quantity

1

001503

Pnl:Powermax800/900 Pwr Unit Plastic Rear

1

2

003132

Circuit Breaker SA:4Pole 480V W/TC

S1

1

3

128405

Contactor Replacement:Powermax800/900

CR1

1

129300

Regulator SA:Powermax800/900 Pwr Unit

1

4

011072

Filter:20 Micron 1/8FPT

1

5

015285

Male Connector:1/8NPTX1/4Push in Tube

1

6

011079

Filter Element for 011072 Filter

1

129357

Linecord Panel SA:Powermax900 CE Pwr Unit

1

7

001571*

Panel:Powermax800/900 Power Cord & EMI

1

8

008782

Strain Relief:3/4NPT .375-.500

1

109068***

Toroid:Powermax1100/900

1

9

129376

Power Cord SA:PMX900-CE/200-230-

1

10

041505

PCB Assy:Powermax800/900-CE Line Filter

1

11

123099**

Cable: Powermax800 Machine Interface

Notes:

Bold part numbers and descriptions are subassemblies.

Indented normal type items are components of subassemblies

All mounting hardware in power supply drawings shown for reference only.

*

Use 129372 to replace power cord rear panel if you have the machine interface
option.

**

Available only with the machine interface option

*** Not shown in Figure 6-4

See also Section 4 Parts List - 208/240/480V, and Section 5 Parts List -
200/230/400V
to identify parts for other Powermax900 power supplies.

5-99