Type

Value

Unit

R/W

Reset

0x1002

UNSIGNED16

TxPGN0 cycle time

default: 15 ms
min� 15 ms, max� 50000 ms

ms

R/W

X

0x1003

UNSIGNED8

TxPGN0 priority

default: 1
min� 0 / max� 7

R/W

X

0x1100

UNSIGNED8

Transmit parameter groups

number 1 active�

TxPGN1
4-byte angle longitudinal X
4-byte angle lateral Y

0: is not sent cyclically
1: is sent cyclically

R/W

0x1101

UNSIGNED8

1 byte TxPGN1 LSB

PGN1: FFXX

default: 0xFF01

R/W

X

0x1102

UNSIGNED16

TxPGN1 cycle time

default: 15 ms
min� 15 ms, max� 50000 ms

ms

R/W

X

0x1103

UNSIGNED8

TxPGN1 priority

default: 1
min� 0 / max� 7

R/W

X

8.2 System settings 0x2000 - 0x207F)

Index

Type

Value

Unit

R/W

Reset

0x2000

UNSIGNED8

Device address

default 25

R/W

X

0x2001

UNSIGNED16

Baud rate

default 250

Kbit

R

X

0x2002

UNSIGNED8

Flag to reset MC
flag = 1

MC reset

R/W

0x2040

UNSIGNED8

Flag for quadrant correction
0: off
1: on → ± 180°
2: on

0° - 360°

R/W

0x2041

UNSIGNED8

Flag for heating
flag = 0

heating off

flag = 1

heating on

R/W

Advertising