10 other sensor functions, 1 device address (0x2000) and baud rate (0x2001), 2 limit frequency digital filter (0x2043) – ifm electronic JN2301 User Manual

Page 16: 3 set zero point (0x2046), 4 terminating resistor (0x2045), 5 set teach (0x2042h)

Advertising
background image

Inclination sensor JN

16

10 Other sensor functions

10.1 Device address (0x2000) and baud rate (0x2001)
In the case of a change the device address and baud rate do not become effective

until after a reset (reset application, reset communication or hardware reset)�

The inclination sensor from ifm is delivered with the device address 25 and a baud rate of 250

Kbits/s�

10.2 Limit frequency digital filter (0x2043)
With the sensor it is possible to make continuously arising angle values insensitive

to external interfering vibrations�

Using a configurable filter (digital FIR filter) interfering vibrations can be

suppressed� The limit frequency of the filter is set via the FIR filter step (index

2043h)�
10.3 Set zero point (0x2046)
To set the zero point the sensor is rotated to the requested position and the current

position is set as "0"� The value of the parameter "set zero point X and Y axes"

(index 2046h) is to be set to 1�
The sensor then calculates the offset to the zero point shift and saves it in the

permanent memory� From then on the offset is subtracted from the angle�
10.4 Terminating resistor (0x2045)
In bus topology a system is terminated with terminating resistors (120 Ω) at the

beginning and end� If the sensor is at the beginning or end, the terminating resistor

(index 2045h) integrated in the sensor can be activated by writing the value 1�

10.5 Set teach (0x2042h)
Should it not be possible to integrate the inclination sensor into the measured

object so that the coordinate system of the sensor and object coordinate system

match, the teach function enables the creation of a new reference system�

The new reference system X

b

,Y

b

, Z

b

is defined so that its Z

b

direction corresponds

Advertising