14 factory setting – ifm electronic JN2301 User Manual

Page 20

Advertising
background image

Inclination sensor JN

20

14 Factory setting

Index

Type

Value

Delivery

0x1000

u8

TxPGN0 active

1: is sent cyclically

0x2000

u8

Device address

25

0x2001

u16

Baud rate

250 Kbits

0x2040

u8

Flag for quadrant correction

1: corresponds to "± 180°”

0x2041

u8

Flag for heating

1: corresponds to "heating on"

0x2042

u8

Index teach value of the X/Y/Z axes

2: corresponds to "absolute measurement"

0x2043

u8

FIR filter step

2: corresponds to "FIR lowpass 5Hz"

0x2044

u8

Angle calculation

0: corresponds to "perpendicular"

0x2045

u8

CAN 120 Ω terminating resistor

1: corresponds to "activated"

0x2046

u8

Set zero point of the X/Y axes

2: corresponds to "absolute measurement"

Advertising