1 informative (0x2080 – 0x2082) – ifm electronic JN2301 User Manual

Page 12

Advertising
background image

Inclination sensor JN

12

Index

Type

Value

Unit

R/W

Reset

0x2042

UNSIGNED8

Index for teach values

of the X/Y/Z axes
0: no change
1: set teach, relative

measurement
2: reset teach, absolute

measurement

R/W

0x2043

UNSIGNED8

FIR filter step for angle

measurement

0 : FIR deactivated
1 : FIR lowpass 10Hz
2 : FIR lowpass 5Hz
3 : FIR lowpass 1Hz
4 : FIR lowpass 0�5Hz

R/W

0x2044

UNSIGNED8

Angle calculation
0: perpendicular
1: Euler
2: gimbal 1X
3: gimbal 1Y

R/W

0x2045

UNSIGNED8

CAN 120 Ohm terminating

resistor
0: resistor deactivated
1: resistor activated

R/W

0x2046

UNSIGNED8

Set index for zero of the
X / Y / Z axes
0: no change
1: activate set zero; relative

measurement
2: reset set zero; absolute

measurement

R/W

0x2047

UNSIGNED8

Output value
0: angle

R/W

0x207F

UNSIGNED8

Factory reset
1: make factory reset

R/W

8.2.1 Informative (0x2080 – 0x2082)

Index

Type

Value

Unit

R/W

Reset

0x2080

INTEGER16

Ambient temperature

1/10 °C

R

0x2081

INTEGER16

MEMS temperature

1/10 °C

R

0x2082

UNSIGNED16

Heating power

mW

R