Advertising
background image

UK

Inclination sensor JN

9

7.3 Configuration examples
Address target unit (ECU): 0x19
Address control unit / master: 0x14
Priority of the message: 3

Example: Set FIR filter for angle measurement to lowpass 5 Hz, index 0x2043/2
Master → ECU

CAN identifier

8-byte data frame

0xCEF1914

0x43

0x20

0x01

0x00

0x02

0x00

0x00

0x00

Response master ← ECU, status code: OK

0xCEF1419

0x43

0x20

0x01

0x00

0x02

0x00

0x00

0x00

Example: Read FIR filter for angle measurement, index 0x2043


Master → ECU

CAN identifier

8-byte data frame

0xCEF1914

0x43

0x20

0x00

0x00

0x00

0x00

0x00

0x00

Response master ← ECU, status code: OK

0xCEF1419

0x43

0x20

0x00

0x00

0x02

0x00

0x00

0x00

7.4 Proprietary PDU format 2 messages
The measured data of the JN2301 sensor is sent cyclically via proprietary PDU

format 2 messages� PDU format (PF) corresponds to the value 0xFF� In this case

the PDU-specific byte (PS) is the group extension (GE); it can be freely set by the

user in the range 0x00 – 0xFF�
In the following these parameter groups are called transmit PGNs (TxPGNs)�
JN2301 supports two TxPGNs:
TxPGN0

2-byte angle information longitudinal X, 2-byte angle information lateral Y
TxPGN1

4-byte angle information longitudinal X, 4-byte angle information lateral Y