Preparation guidelines and minimum thicknesses

Successful results with IPS Empress Esthetic can only be achieved if the guidelines below and minimum layer thicknesses

are strictly observed.

Inlays and onlays

Static and dynamic antagonist contacts must be taken into consideration. The preparation margins must not be located on

centric antagonist contacts.

A preparation depth of at least 1.5 mm and an isthmus width of at least 1.5 mm must be observed in the fissure area.

Prepare the proximal box with slightly diverging walls and observe an angle of 100 - 120° between the proximal cavity

walls and the prospective proximal inlay surfaces. For inlays with pronounced, convex cavity walls without adequate

support by the proximal shoulder, marginal ridge contacts should be avoided. Round out internal edges in order to prevent

stress concentration within the ceramic material. Eliminate the proximal contacts on all sides. Do not prepare slice-cuts or

feather edges.

For onlays, provide at least 2 mm of space in the cusp areas. On the vestibular side, the shoulder should be prepared with

a chamfer (10°-30°) to improve the aesthetic appearance of the transitions between the ceramic material and the tooth.

Partial crowns are indicated if the preparation margin is less than approximately 0.5 mm away from the cusp tip, or if the

enamel is severely undermined.