Ivoclar Vivadent IPS Empress Esthetic User Manual

Page 44

Advertising
background image

44

Optional

Subsequent adjustments

After completion, additional adjustment (e.g. contact points) may become necessary. For that purpose,

IPS Empress Add-On 770 °C/1418 °F is available.

Processing:

– Before the adjustment, the restoration must be free from dirt and grease. For that purpose, blast the areas to be

adjusted with Al

2

O

3

(Type 100) at max. 0.5 bar pressure and thoroughly clean the restoration using the steam jet.

– Mix IPS Empress Add-On 770 °C / 1418 °F with IPS Empress Esthetic Veneer Build-Up Liquid to a workable consistency.

Make sure that the add-on material and liquid are evenly mixed so that an optimum firing result can be achieved.

– Apply the mixed add-on material on the cleaned, desired areas using a brush and slightly blot them with an absorbent

cloth.

– Position the adjusted restoration on the firing tray and fire in the ceramic furnace.

– After firing, manually polish the supplemented areas to a high gloss.

IPS Empress Esthetic with

B

S

t

T H

V

1

V

2

IPS Empress Add-On 770°C/1418°F

Corrective firing

403°C

4'

60°C

770°C

2'

450°C

769°C

757°F

4'

108°F

1418°F

2'

842°F

1417°F

Firing parameters for the Corrective firing

B = Stand-by temperature °C / °F
S = Closing time/minutes
t

= Temperature increase rate °C/min. / °F/min.

T = Firing temperature °C / °F
H = Holding time / min.

V

1

= Vacuum-on temperature °C / °F

V

2

= Vacuum-off temperature °C / °F

Adjust the proximal contact points

Advertising