Position the IPS Empress Esthetic ingots and AlOx plungers on the IPS UniTray.

Place the investment rings and IPS UniTray with AlOx plungers and ingots in the preheating

furnace.

Preheating

After the stipulated setting time of the respective investment material (IPS PressVEST or IPS Empress Esthetic Speed), the

investment ring is prepared for preheating as follows:

– Remove the ring gauge and ring base with a turning movement,

– Carefully push the investment ring out of the IPS Silicone Ring.

– Remove rough spots on the bottom surface of the investment ring with a plaster knife and check the 90° angle.

– Investment material residue must not enter the sprues. Blow into the sprues if necessary.

– If several investment rings are preheated together, mark them with the respective ingot shade.

Setting time

Temperature of the preheating

furnace

Preheating temperature

Position of the investment ring in

the furnace

IPS Empress Esthetic Ingots

IPS Empress Alox Plunger

Important

IPS PressVEST

min. 60 min.

Room temperature

850°C (1562 °F)

Towards the rear wall; tipped with the

opening facing down

Always preheat

Always preheat

IPS Empress Esthetic Speed

min. 30 min., max. 45 min.

850 °C (1562 °F); switch on

preheating furnace in time

850°C (1562 °F)

Towards the rear wall; tipped with the

opening facing down

Always preheat

Always preheat

If several Speed investments are

required, they should be invested with

a time difference and placed in the

preheating furnace at intervals of

approximately 20 minutes. When

placing the investment rings in the

preheating furnace, make sure that the

furnace temperature does not drop too

much. The indicated holding time starts

when the preheating temperature is

reached again.

In order to ensure smooth working procedures in the laboratory on a daily basis, impeccable functioning of the infra-

structure and the preheating furnaces is essential. This includes their maintenance, cleaning with a vacuum cleaner in a

cool state as well as regular checks of the temperature controls and heating elements, etc. by the manufacturer.