Vacuum-forming the vectris single – version a – Ivoclar Vivadent Vectris User Manual
Page 33

33
SINGLE
CROWNS
Vacuum-forming the Vectris Single –
Version A
Application of Vectris in the Vectris VS1 framework former: Position the die in the framework former, apply a small
amount of Vectris Glue to the die to keep Vectris Single in place while it is on the die. Remove the Vectris Single from the
light-protected package, place Vectris Single on the die using tweezers and lightly press it into place. Next, cover the Vectris
Single with a Vectris foil to reduce the inhibited layer. Then, close the Vectris VS1 unit and start Program 1 to commence
the vacuum-forming and polymerization process. The program takes 10 minutes to complete.
Position the die in the Vectris VS1 unit; apply a small amount of Vectris Glue to the die.
Remove the Vectris Single from the light-protected package; place it on the die with tweezers and lightly press it into place.
Cover with Vectris foil; start Program 1 for the vacuum-forming and polymerization process.