10 en, 4 additional welding functions, Fastmig sf 52w, sf 53w – Kemppi SF 52W User Manual

Page 12: Sf 53w

Advertising
background image

FastMig SF 52W, SF 53W

10

EN

2.4 Additional welding functions

Activation with the MIG function selection button (11)

WIRE INCH

GAS TEST

SET
ON

CH

PANEL

SAVE

SET

ch clear

ch remote

MEMORY

SELECT

quick

setup

weld

data

ARC FORCE

DYNAMICS

4T

2T

SETUP

MMA

PEN

MMA

WISE

1-MIG

MIG

POWER

U

SYNERGIC

PROGRAM

A

V

m/min

mm

SF 53W

W004270

/ MINILOG

The selection button for additional MIG functions can be used to activate the Hot Start, Crater

Fill or WisePenetration (licence required) function. Further presses of the selection button can

select one or more of the above func tions. Only the available additional functions for each

method can be selected.

HotStart function is meant to reduce initial welding errors when welding highly heat-

conductive materials such as aluminium. Hot Start can be selected when using Synergic

1-MIG welding and when the 4T operating mode is selected. In this case, when the start

switch of the gun is held down, a fixed pre-gas time is displayed after which welding

starts at the level determined by the SETUP mode’s Hot Start parameter, returning to the

normal level when the gun switch is released.

WisePenetration™ is a welding function for delivering constant welding power

regardless of changes in the stick out length. It is an optional feature, which can be

purchased through Kemppi DataStore.

Crater Fill is meant to reduce welding defects caused by end cratering. The Crater Fill

function can be selected when using Synergic 1-MIG welding and when the 4T operating

mode is selected. When the gun switch is pressed down in connection with termination

of welding, the welding power drops to the crater-filling level selected previously. The

crater filling function is discontinued by releasing the gun switch.

NOTE!

In crater fill, the initial value of the welding power must be greater than the final

value, and therefore the adjustment ranges for the initial and final values are restricted

automatically, if necessary.

Welding Level

Crater Fill Start Level

Crater Fill Time

Crater Fill End Level

Parameters related to these functions are set via the SETUP function (see ’SETUP functions’).
Stopping is performed as with the normal 4T function.
The values of parameters related to additional MIG functions can be changed either with the

SETUP function (see ’SETUP’) or with the Quick SETUP function. Quick SETUP is activated by

simultaneously pressing buttons 1 and 3. In this way, parameters related to MIG additional

functions can be set.
Parameters are selected for adjustment via potentiometer on the left. The value of the

parameter is set via potentiometer on the right. The value is immediately recorded in the

memory.

Advertising
This manual is related to the following products: