Synergic Start Time

FSt

-9 ... +9

0

Start time in WiseRoot/WiseThin welding

Synergic Start

Voltage

FuL

-30 ... +30

0

Voltage level in the beginning of
WiseRoot/WiseThin welding

Start Power

StA

-9 ... +9

0

Strength of start pulse
(not in WiseRoot/WiseThin)

Post Current Time

PoC

-9 ... +9

0

Post current

Synergic MIG Unit

Unl

m/min, mm, A m/min

In 1-MIG and WiseRoot welding, the
parameter shown in left-hand display:
wire feed speed (m/min), sheet thickness
(mm) or average current (A)

Arc Voltage

Ard

OFF, on

OFF

on: Display shows arc voltage
OFF: Display shows pole voltage
(not in WiseRoot/WiseThin)

Cable Length

CAb

std, 5 – 80m

std

Cable loss is calculated for optimal arc
control and for the Arc Voltage display
(not in WiseRoot/WiseThin)

Common Setup -parameters for MIG processes

Name of parameter

Name on

display

Parameter

values

Factory

setting

Description

Device Address

Add

3 or 6

3

Wire feeder bus address

Using features of PMT

Gun

Gun

OFF, on

on

on = PMT gun
OFF = other gun

Gas Guard Connected

GG

no, YES

no

Implementation of gas guard

LongSystem Mode

LSY

OFF, on

OFF

on: Gives optimum welding characteristics
with long welding cables. Recommended
to be used when the cable length exceeds
40 m.

Code Entry

Cod

---, Ent

---

Entering license codes manually:
1. Adjust right potentiometer to (‘Ent’).
2. Press REMOTE.
3. Set code with right potentiometer.
4. Choose next with left potentiometer.
5. Go back to point 3, until all codes have
been set.
6. Approve by pressing REMOTE. (‘Suc cEs’)

PIN Code Entry

PIn

---, PIn

---

Enters pin code for Panel Locking

Panel Locking

LoC

OFF, on

OFF

Enables panel locking

Water Cooler

Coo

OFF, on

on

Enables water cooler

Wire Inch Stop

Inc

OFF, on

on

OFF = Stops wire inch in case arc does not
ignite
on = Feeds wire as long as the welding
gun start switch is pressed.

Auto Wire Inch

AIn

OFF, on

on

SuperSnake Automatic Wire Inch
function. Wire Inch button runs the filler
wire from the wire feeder up to the
SuperSnake.

Demo Licence Time

dEt

3-h, 2-h, **’,
**’’, OFF

The remaining time for the WiseDemo
licence
(readable value only).
3-h = max. 3 hours left
2-h = max. 2 hours left
**’ = ** minutes left
**’’ = ** seconds left
OFF = Demo period has expired.