2.3 SF 52W and SF 53W operations

ON/OFF button (1)
The wire feed unit remains in the OFF position when the power source is switched on, thus

preventing start-up. ’OFF’ is shown on the display.
When the ON/OFF button is pressed for more than 1 second, the unit starts up. The unit is now

ready for welding and will automatically return back to it previous position, before the power

was cut off. The wire feed unit starts up also by pressing three (short) times the switch of the

welding gun.
Basic settings and displays
With MIG welding the wire feed speed is set via left potentiometer (control knob) and the

value is shown on the left display. The welding voltage is set via right potentiometer (control

knob) and the value is shown on the right display. During welding, the left display shows the

actual welding current value and the display on the right shows the welding voltage.
With electrode welding (MMA) the welding current value is set via the potentiometer and

the value is shown on the left display. The display on the right shows the idling voltage of the

power source. During welding the left display shows the actual welding current value and the

display on the right shows the welding voltage.
When MIG dynamics/electrode welding Arc force adjustment is activated with Arc Force/

Dynamics button the value is adjusted via right potentiometer (control knob) (see the

information on adjustment of MIG dynamics/arc force).
With Synergic 1-MIG welding, the power value is set via left potentiometer (control knob) and

the length of the arc via right potentiometer (control knob) (see ’1-MIG welding’).
Adjustment of MIG dynamics/Arc Force (3)

With MIG welding dynamics adjustment is influenced on welding stability and spatter

amount. Zero setting is recommended basic setting. Values –> min (-1 ... -9), softer arc for

reduced spatter amount. Values –> max (1 ... 9), harder arc for increased stability and when

100 % CO₂ shielding gas is used when welding steel.
With electrode welding Arc Force adjustment is influenced on welding stability. Adjustment

is needed for using different types of electrodes. Control range (-9 ... 0) is commonly used

for welding electrodes for stainless steel. Control range (0 ... +9) is used for harder arc

characteristic to increase stability, e.g. for welding with thicker basic electrodes and using

lower current value than recommendated. Factory set value (0) is a good general use for

adjusting the roughness of the arc.
Indication of liquid-cooled MIG gun (4)


You can activate either liquid- or air-cooled MIG gun with a setup parameter. For more

information, see chapter 2.6.
If the LED (4) is lit, liquid-cooling is activated in the system. In this case, ensure that you have

connected a liquid-cooled MIG gun to the equipment. The cooling units starts on the next

machine startup.