Kemppi oy / 1515, Sf 53w – Kemppi SF 52W User Manual

Page 9

Advertising
background image

7

© Kemppi Oy / 1515

EN

Gas test (5)

The gas test button opens the gas valve without activating the wire feed or power source. Gas

flows for 20 seconds by default. The display shows the remaining gas flow time. The default

time of gas flow can be adjusted via the right-hand potentiometer within a range of 0 to 60

seconds. The new time setting is recorded in the memory. The gas flow can be discontinued

by pressing the ON/OFF button or the start switch of the gun.
Weld data (6)

The weld data function is activated by pressing buttons 5 and 7 simultaneously. The weld

data function returns the welding current and voltage values to the displays that were in use

during the last weld.
Wire inch (7)

The wire inch button starts the wire feed motor without opening the gas valve and without

engaging the power source. The default wire feed speed is 5 m/min. The speed can be

adjusted via the right-hand potentiometer. When the button is released, the wire feed stops.

Operation returns to normal approx. 3 seconds after release of the button or if the ON/OFF

button is pressed briefly.
Selection of welding process (11)

WIRE INCH

GAS TEST

SET
ON

CH

PANEL

SAVE

SET

ch clear

ch remote

MEMORY

SELECT

quick

setup

weld

data

ARC FORCE

DYNAMICS

4T

2T

SETUP

MMA

PEN

MMA

WISE

1-MIG

MIG

POWER

U

SYNERGIC

PROGRAM

A

V

m/min

mm

SF 53W

W004270

/ MINILOG

The welding process – normal MIG, 1-MIG or Wise – can be chosen by the welding process

selection button. In normal MIG welding wire feed speed and welding voltage is adjusted

separately. In synergic 1-MIG and Wise welding the welding voltage and other parametres

related to welding are optimally bound to each other! In synergic welding the setting for

power and arc lenght are adjusted.
Wise welding is the facility provided separately, so the function is not in every equipment.
Electrode welding (MMA) is selected by pressing the button for >1 second.

NOTE!

When electrode welding is selected, the power source, the electrode holder connected to it

and the MIG gun become energised (open circuit voltage).

Advertising
This manual is related to the following products: