Kemppi oy / 1515, Sf 53w – Kemppi SF 52W User Manual
Page 9

7
© Kemppi Oy / 1515
EN
Gas test (5)
The gas test button opens the gas valve without activating the wire feed or power source. Gas
flows for 20 seconds by default. The display shows the remaining gas flow time. The default
time of gas flow can be adjusted via the right-hand potentiometer within a range of 0 to 60
seconds. The new time setting is recorded in the memory. The gas flow can be discontinued
by pressing the ON/OFF button or the start switch of the gun.
Weld data (6)
The weld data function is activated by pressing buttons 5 and 7 simultaneously. The weld
data function returns the welding current and voltage values to the displays that were in use
during the last weld.
Wire inch (7)
The wire inch button starts the wire feed motor without opening the gas valve and without
engaging the power source. The default wire feed speed is 5 m/min. The speed can be
adjusted via the right-hand potentiometer. When the button is released, the wire feed stops.
Operation returns to normal approx. 3 seconds after release of the button or if the ON/OFF
button is pressed briefly.
Selection of welding process (11)
WIRE INCH
GAS TEST
SET
ON
CH
PANEL
SAVE
SET
ch clear
ch remote
MEMORY
SELECT
quick
setup
weld
data
ARC FORCE
DYNAMICS
4T
2T
SETUP
MMA
PEN
MMA
WISE
1-MIG
MIG
POWER
U
SYNERGIC
PROGRAM
A
V
m/min
mm
SF 53W
W004270
/ MINILOG
The welding process – normal MIG, 1-MIG or Wise – can be chosen by the welding process
selection button. In normal MIG welding wire feed speed and welding voltage is adjusted
separately. In synergic 1-MIG and Wise welding the welding voltage and other parametres
related to welding are optimally bound to each other! In synergic welding the setting for
power and arc lenght are adjusted.
Wise welding is the facility provided separately, so the function is not in every equipment.
Electrode welding (MMA) is selected by pressing the button for >1 second.
NOTE!
When electrode welding is selected, the power source, the electrode holder connected to it
and the MIG gun become energised (open circuit voltage).