3 button functions, 1 on/off button (1), 2 dynamics button (2) – Kemppi MXP 37 Pipe Stee User Manual

Page 18: 3 gas test button (3), 4 wire inch button (3), 5 channel down button (5) xf 37, 6 channel up button (6) xf 37, Fastmig mxp 37 pipe, mxp 38

Advertising
background image

EN

3.3 Button functions

3.3.1 ON/OFF button (1)

XF 37

W007241

CH REMOTE

CHANNEL

PANEL

4T
2T

Short press: XF 37 / X 38 panel returns to initial display.
Long press: XF 37 / X 38 panel is turned ON or OFF.

NOTE!

When wire feeder XF 37 / XF 38 control panel is turned ON, also the power source control

panel X 37 turns on and links automatically to this wire feeder.

3.3.2 Dynamics button (2)

XF 37

W007241

CH REMOTE

CHANNEL

PANEL

4T
2T

Short press: Dynamics setting for 1-MIG, synergic MIG and CC/CV. ArcForce setting for MMA.
Long press: Wire feeder number selection. If there is more than one wire feeder connected to

the system, you can select which of them is active. Each wire feeder has its own number (1–3).

NOTE!

Wire feeder number is not available in MMA, CC and CV processes.

3.3.3 Gas test button (3)

XF 37

W007241

CH REMOTE

CHANNEL

PANEL

4T
2T

This button displays the gas test time. You can change it with the control knob.
Gas test starts when the time adjustment is made, after a short delay.
You can stop gas test by pressing any button.

3.3.4 Wire inch button (3)

XF 37

W007241

CH REMOTE

CHANNEL

PANEL

4T
2T

This button starts feeding the wire with the default speed of 5.0 m/min. The wire feed stops

when you release the button.
You can change the wire feed speed with the control knob. The changed speed is used if you

press the button again.

3.3.5 Channel down button (5)

XF 37

W007241

CH REMOTE

CHANNEL

PANEL

4T
2T

WISEROOT

+

/

This button selects the previous memory channel that can be found.

3.3.6 Channel up button (6)

XF 37

W007241

CH REMOTE

CHANNEL

PANEL

4T
2T

WISEROOT

+

/

Short press: Selects the next memory channel that can be found.
Long press: Locks or unlocs the selected memory channel. No parameter changes are allowed

to a locked memory channel.

FastMig MXP 37 Pipe, MXP 38