7 2t/4t button (7), 8 extra functions button (8), 9 remote selection button (9) – Kemppi MXP 37 Pipe Stee User Manual
Page 19: 10 power control knob (10), 11 arc length and voltage control knob (11), Kemppi oy / 1515

EN
3.3.7 2T/4T button (7)
XF 37
W007241
CH REMOTE
CHANNEL
PANEL
4T
2T
Short press: Toggles between 2T or 4T gun trigger mode.
Long press: Turns MatchLog ON/OFF. This can be either MatchChannel or Minilog
functionality, depending on which one is defined in the selected memory channel. If neither
one is defined, this selection is unavailable.
3.3.8 Extra functions button (8)
XF 37
W007241
CH REMOTE
CHANNEL
PANEL
4T
2T
Short press: Selects Crater fill or Hot start function.
Long press: Turns MMA/CC/CV mode ON/OFF.
3.3.9 Remote Selection Button (9)
XF 37
W007241
CH REMOTE
CHANNEL
PANEL
4T
2T
Short press: Toggles the control between the control panel, gun remote control unit and
hand-held remote control unit.
NOTE!
If RemoteAutoRecog setting is ON in X 37 control panel, you can select only those remote
controls, which can be found in the system.
Long press: Turns the memory channel remote selection ON/OFF. This is available only if you
have selected either gun remote control unit or hand-held remote control unit. Not available
in MMA/CC/CV mode.
3.3.10 Power control knob (10)
XF 37
W007241
CH REMOTE
CHANNEL
PANEL
4T
2T
This control knob adjusts
• wire feed speed or power in MIG/MAG processes (before or during welding)
• MMA/CC current level (before or during welding)
• selected parameter values.
3.3.11 Arc length and voltage control knob (11)
XF 37
W007241
CH REMOTE
CHANNEL
PANEL
4T
2T
This control knob adjusts the arc length, voltage or selected parameter values before or
during welding.
17
© Kemppi Oy / 1515