Shield gas – Kemppi Promig 100 User Manual

Page 12

Advertising
background image

12 – Promig 100/0450

©

COPYRIGHT

KEMPPI

OY

41

2.2.8. Adjustment of tightness of reel brake (Promig 501, 501L and 530)

Brake force is adjusted through hole in locking device of reel hub by screwing the control screw

(41) with screwdriver.
Adjust brake force as so big that the wire is not allowed to become too loose on the reel so that

it would spill from the reel when the rotation of the reel stops. Need for brake force is increased

with increase of wire feed speed.
Since the brake loads for its part the motor, you shouldn’t keep it unnecessarily tight.

2.2.9. Burn back time

Electronics of feed unit controls stopping of welding automatically so that the wire end doesn’t

melt fastened to the contact tip or the work piece. Automatics work regardless of the wire

feed speed.

2.2.10. Ground cable

Fasten earthing press of ground cable carefully, preferably direct to welding piece. Contact

surface of press always should be as large as possible. Clean the fastening surface from paint

and rust!
Use in your MIG equipment 70 mm

2

. Thinner cross-sectional areas might cause overheating of

connectors and insulations.
Make sure that the welding gun in your use is designed for max. welding current needed by

you!
Never use a damaged welding gun!

2.3. SHIELD GAS

Handle gas bottle with care. There is a risk for injury if gas bottle or bottle valve

is damaged!

For welding steels, mixed gases are normally used. Check that the regulator is suitable for the

gas. The flow rate is set according to the welding power used in the job. A suitable flow rate is

normally 8 - 10 l/min. If the gas flow is not suitable, the welded joint will be sporous. Contact

your local Kemppi-dealer for choosing gas and equipment.

2.3.1. Installing gas bottle

Always fasten gas bottle properly in vertical position in a special holder on the

wall or on a carriage. Remember to close gas bottle valve after having finished

welding.