3. CONTROL PANEL OPERATIONS

Welding method selection (S1): MIG / MMA (MIG two-sequence procedure or four-sequence

procedure is determined according to mode selection of the Promig 501, 501L and 530.
Control mode selection: (S2) local control / remote control, (S3) remote control unit / gun

control unit
Local controls: wire feed speed/MMA current (R1), welding voltage (R2)
Warning light for thermal shield (H11)

3.1. WELDING METHOD SELECTING SWITCH

MMA

MMA welding with stepless welding current control
MIG

MIG welding, the switch of the Promig 100 must be on this position when

the MIG welding is started

MIG two-sequence procedure is selected on the Promig 501, 501L and 530 panel.

MIG/MAG welding with two-sequence procedure of welding gun start switch.
1. switch pressed: welding starts

2. switch open:

welding stops

MIG four-sequence procedure is selected on the Promig 501, 501L and 530 panel.

MIG/MAG welding with four-sequence procedure of welding gun start switch.
1. switch pressed: shielding gas flow starts

2. switch open:

welding starts

3. switch pressed: welding stops

4. switch open:

shielding gas flow stops

Local control: Control potentiometers R1 and R2 on panel are used.
Remote control: Adjustments are carried out from remote control unit

R20 which is connected to remote control connector X4 of subfeeder.

If you use the remote control unit R10, adjust wire feed speed or MMA welding

current with potentiometer of the R10 and voltage with potentiometer U on panel.
Gun control: Wire feed speed is adjusted with control module RMT which is

connected to Kemppi PMT welding gun and welding voltage is adjusted with

potentiometer U on panel.

3.2. THE PROMIG 501, 501L AND 530 HAS THE MC CONTROL PANEL

Control mode selecting switch