Installation, Operation safety, Assembly of the mig system – Kemppi Promig 100 User Manual

Page 7

Advertising
background image

Promig 100/0450 – 7

©

COPYRIGHT

KEMPPI

OY

1.3. OPERATION SAFETY

Please study these Operation safety instructions and respect them when installing, operating and

servicing the machine.

Welding arc and spatters

Welding arc hurts unprotected eyes. Be careful also with reflecting arc flash. Welding arc and

spatter burn unprotected skin. Use safety gloves and protective clothing.

Danger for fire or explosion

Pay attention to fire safety regulations. Remove flammable or explosive materials from welding

place. Always ensure that you have sufficent fire fighting equipment available where you are

welding. Be prepared for hazards in special welding jobs, eg. for the danger of fire or explosion

when welding containertype work pieces. Note! Fire can break out from sparks even several

hours after the welding work has been finished!

Mains voltage

Never take welding machine inside a work piece (eg. container or truck). Do not place welding

machine on a wet surface. Always check cables before operating the machine. Change damaged

cables without delay. Damaged cables may cause an injury or set out a fire. Connection cable

must not be crushed, it must not touch sharp edges or hot work pieces.

Welding power circuit

Isolate yourself by using proper protective clothing, do not wear wet clothing. Never work on

a wet surface or use defect cables. Do not put the MIG-gun or welding cables on welding

machine or on other electric equipment. Do not press the MIG-gun switch, if the gun is not

directed towards a work piece.

Welding fumes

Take care that there is sufficient ventilation during welding. Take special safety precau-

tions when welding metals which contain lead, cadmium, zinc, mercury or beryllium.

2. INSTALLATION

2.1. ASSEMBLY OF THE MIG SYSTEM

1 Installation of power source

Read paragraph ”Installation” in operation instructions 1913170 for Pro power sources and

carry out the installation according to that.

2 Mounting of Pro power source to transport wagon

P40 6185261, air-cooled MIG system mounting

P30W 6185262, liquid-cooled MIG system mounting

3 Put the Promig 501, 501L and 530 onto the power source and lock it with bolts to handles

of power source, or mount to the wire feeder cables and roll carriage which extend the reach,

see page 7

4 Mount the control panel to the Promig 501, 501L and 530

MC 6263501

ML

6263502

MXE 6263503

5 Mount the synchronization set to the Promig 501, 501L and 530

Prosync 50 6263121

6 Connecting cables

Connect cables according to figures.

Air-cooled system. Liquid-cooled system.

You can change polarity of filler wire by interchanging the Promig welding current cable and

earth cable with welding cable connectors of Pro power source.

Advertising