2

2. Synergetic quick pulse

Press the PULSE button twice and the synergetic light turns on. Pulse parameters are calculated

automatically when average welding current is selected. Other pulse selections are not

necessary.

2. Long pulse

Long pulse method gives you the possibility to adjust all pulse parameters (pulsing frequency,

pulse ratio, pulse current and pause current). You can also adjust the welding current, in which case

you receive a new pulse current value. Pulse ratio and pause current percentage remain constant.

When you adjust the pulse ratio, pulse current or pause current, the new average welding current

value is shown on the display.

3.2.2.6. TIG welding panel MTZ – pulsed TIG and MINILOG function

1. Minilog
2. Minilog 10 – 90 % of welding current

1. MTZ Minilog

When torch switch is pressed current goes to search arc; after the switch is released current goes to

welding current within the upslope time. With Minilog operation you can select from two current

levels: the welding current and the Minilog current. You can move from one to the other by quickly

pressing the torch switch. Press torch switch for 1 second, current goes to downslope and then to

the tail arc. Current stops when the switch is released.