3.2.2.7. TIG welding panel MTM – pulsed TIG and MINILOG function with

memory

1. Minilog
2. Selection of memory function
3. Selection of channel in memory function
4. Minilog 10 – 90 % of welding current
5. SAVE

1. Minilog operation

When torch switch is pressed gas flow starts. When you release the switch current goes to search

arc. A quick press on the switch, and current goes to welding current within the upslope time. After

another short press it goes to Minilog operation, and you can select from two current levels: the

welding current and the Minilog current. You can move from one to the other by quickly pressing

the torch switch. Press the torch switch for 1 second, release it and current goes to downslope.

3.2.3. Saving welding settings (MTM)

MTM panel has 10 memory channels for user settings. The selections are made in the MEMORY

field. Not only welding parameters but also function selections can be saved in the memory. MMA

welding values can also be stored in memory channels. Proceed as follows:

1. Press MEMORY button twice and if the SET light starts blinking the channel is free. If the

channel is reserved the led will remain lit.

2. Select memory channel by pressing CH button.
3. Select the parameters and press SAVE button.
4. Press MEMORY button twice. ON led is lit.
5. Start welding and adjust settings if necessary.