Installation of the panel, Mains connection – Kemppi MLS 2500 User Manual

Page 5

Advertising
background image

Master MLs™ 500, 503, 3500, 3503, Mastertig MLs™ 3000, 3003, 4000, 4003 / 0649– 5

© keMppi oy

1

2

1

.

2.

Rear of machine

1. Mains switch
2. Snap connector for gas

Torch

Installing gas-cooled

torch

Installing water-cooled torch

2.5. INSTALLATION OF THE PANEL

1. Fasten the cable connectors of the function panel to the power source (2 pieces).

2. Place the bottom edge of the panel behind the securing clips on the machine. Remove the

fixing pin from the top edge with, for example, a screwdriver. Then gently push the upper

part of the panel into place. Make sure that the cables do not get damaged, continue gently

pushing the upper part of the panel until it clips into place. Finally, push the fixing pin back

into its place.

2.6. mAINS CONNECTION

Only an authorised electrician is allowed to install mains cable and plug!

The power source is equipped with a 5-meter mains cable without plug. The plug may be installed

by an authorised electrician only. The fuse and cable sizes are given in the Technical data at the

end of this manual.

This equipment’s electromagnetic compatibility (EMC) is designed for use in an

industrial environment. Class A equipment is not intended for use in residential location

where the electrical power is provided by the public low-voltage supply system.

Advertising