Adopting the saved settings, Setup functions – Kemppi MLS 2500 User Manual

Page 16

Advertising
background image

16 – Master MLs™ 500, 503, 3500, 3503, Mastertig MLs™ 3000, 3003, 4000, 4003 / 0649

© keMppi oy

If the saved settings need to be adjusted the led has to be moved from ON to SET position in order

to select parameters. Press the SAVE button. It is also possible to save the currently used parameters

by pressing SET when the memory function is in OFF state (no lights on). Channel is cleared if

MEMORY and CH buttons are pressed simultaneously in SET mode.

3.2.4. Adopting the saved settings

1. Select MEMORY by pressing the button.
2. Select memory channel by pressing the CH button.
3. Start welding.

3.2.5. Remote control memory channels

Memory channels are selected by pressing simultaneously both REMOTE and CH button. With

the remote control you can retrieve saved settings on memory channels.

3.2.6. SETUP functions

A so called SETUP state is included for modifying panel functions. You can enter the SETUP state

by pressing the REMOTE (SETUP) button longer than normally. Exit is performed in the same

way. You can select the function (see list below) by pressing the arrow buttons and then change

the setting by turning the potentiometer.

display Function

Factory setting

A1

upslope with constant time setting /
gradient (steepness) setting

0

constant time

A2

downslope with constant time setting /
gradient (steepness) setting

0

constant time

A3

tig antifreeze off / on

1

off

A4

mmA antifreeze off / on

1

on

A5

mmA hot start pulse non adaptive / adaptive

0

non adaptive

A6

downslope cut off on / off

0

on

A7

mmA open circuit voltage 80v / 40v

0

80 v

A8

2t downslope normal / cuts off by short switch action

0

normal

A9

tacking automatics off / on

0

off

A10

Current at arc start steep / slightly sloped

0

steep.

A11

downslope linear / non-linear

0

linear

A12

mmA/tig method selection with remote control off /on

0

off

A13

search arc off / on

1

on

A14

Possibility to current freezing during downslope off / on

0

off

A15

Control of channels with torch up-down switch off / on

0

off

A16

Control of current with torch up-down switch always active /
active only when selected with remote button

0

always active

A17

guard functions of cooling unit not activated / activated

1

activated

A18

downslope for minilog and 4t in mtm and mtl panels
performed during long switch action / after switch operation
(normal)

0

normal

A19

Cooling unit operates on forced control / automatic on/off
control

0

automatic