Installation, Removal from packaging, Locating the machine – Kemppi MLS 2500 User Manual

Page 4: Serial number, Installation and main parts

Advertising
background image

4 – Master MLs™ 500, 503, 3500, 3503, Mastertig MLs™ 3000, 3003, 4000, 4003 / 0649

© keMppi oy

1

2

3

5

4

6

Welding power circuit

Isolate yourself by using proper protective clothing, do not wear wet clothing. Never work on a

wet surface or use damaged cables. Do not put TIG torch or welding cables on welding machine

or on other electric equipment. Do not press TIG torch switch if the torch is not directed towards

the work piece.

Welding fumes

Take care that there is sufficient ventilation during welding. Take special safety precautions when

welding metals which contain lead, cadmium, zinc, mercury or beryllium.

Lifting the equipment

Always remove gas bottle before lifting.

2. INSTALLATION

2.1. REmOvAL FROm PACkAgINg

The equipment is packed in durable packages designed especially for it. However, it is necessary

to check the equipment before using it to make sure that the equipment or any part of it has not

got damaged during transportation. Also check that the delivery corresponds to your order and

that you have received all necessary instructions for installing and operating the equipment. The

packaging material is recyclable.

2.2. LOCATINg THE mACHINE

Place the machine on a horizontal, stable and clean ground. Protect the machine from rain and

direct sunshine. Check that there is enough space for cooling air circulation in front of and behind

the machine.

2.3. SERIAL NumbER

Serial number of the machine is marked on the rating plate. The serial number is the only proper

means of identifying parts for a specific product. It is important to make correct reference to the

serial number of the product when making repairs or ordering spare parts.

2.4. INSTALLATION ANd mAIN PARTS

Front of machine

1. Function panel
2. Remote control connector
3. TIG torch control connector, not in MMA

version

4. Shield gas and current connector for TIG

torch, not in MMA version

5. (+) connector for electrode holder or earth

cable, in TIG welding for earth cable

6. (-) connector for earth cable or electrode

holder in MMA welding (stick welding)

Markings for (+/-) poles on the machine front are

embossed.