Foot pedal control r11f, Cooling unit operation mastercool 10, Storage – Kemppi MLS 2500 User Manual

Page 17

Advertising
background image

Master MLs™ 500, 503, 3500, 3503, Mastertig MLs™ 3000, 3003, 4000, 4003 / 0649– 1

© keMppi oy

3.2.7. Foot pedal control R11F

First read under ”3.2.2.4. TIG welding panel MTL” point ”6. Remote control” for installing the

remote control ready for operation. Foot pedal R11F is used in TIG welding, and its control range

is adjustable. The minimum value of control range is set with the panel potentiometer when the

pedal is not pressed, display shows ”LO”. Control range maximum is set similarly by pressing

first the PEDAL LO/HI button on the panel, display shows ”HI”. Welding is started with a light

press on the pedal, the arc ignites to the set minimum current. Welding current goes to maximum

when the pedal is pressed to the bottom. The arc is broken when the pedal is released. Adjust again

if necessary.

3.3. COOLINg uNIT OPERATION mASTERCOOL 10

The operation of cooling unit Mastercool 10 is controlled by the power source. The cooling unit

pump starts automatically when welding starts. Proceed as follows:

1. Start power source.
2. Check water level and input flow of the reservoir, add liquid if needed.
3. If you use a water-cooled torch you can fill it with water by pressing WATER FILL

(HF CONTACT) button for more than 2 seconds.

The pump operates for 5 another minutes after welding has been finished to cool the water to the

same temperature as in the machine surrounds. This reduces the need of service.

Thermal overload

The thermal overload light is lit, the machine stops and display shows COOLER when temperature

control of the machine has detected cooling water overheating. The cooling unit fan cools down

the water, and when the light goes out welding can be started again.

Water flow signal

Display shows COOLER when water flow is blocked.