Maintenance, Regular maintenance 4.1.1. every sixth months, Service contract – Kemppi MLS 2500 User Manual

Page 18: Troubleshooting

Advertising
background image

1 – Master MLs™ 500, 503, 3500, 3503, Mastertig MLs™ 3000, 3003, 4000, 4003 / 0649

© keMppi oy

4. mAINTENANCE

Watch out for mains voltage when handling electric cables!

Degree and circumstances of machine utilisation should be taken into consideration when planning

product maintenance. Careful use and preventive maintenance help to avoid unnecessary production

disturbances and breaks. Check the condition of the welding and connection cables daily. Do not

use damaged cables.

4.1. REguLAR mAINTENANCE
4.1.1. Every sixth months

NOTE! Disconnect the plug of the machine from the mains socket and wait for ca. 2 minutes

(capacitor charge) before removing the casing plate.
The following maintenance operations should be carried out at least every sixth months:

• Electric connections of the machine – clean any oxidised parts and tighten any loose

ones. NOTE! You must know the correct tension torques before you start repairing the

connections.

• Clean the inner parts of the machine from dust and dirt e.g. with a soft brush and a vacuum

cleaner. Do not use compressed air because there is the danger that the dirt is packed even

more tightly in the gaps of the cooling profiles. Do not use a pressure washer.

Only an authorised electrician may repair the machine.

4.1.2. Service contract

KEMPPI service workshops make special service contracts with customers about regular

maintenance. All parts are cleaned, checked and if necessary, repaired. Also the operation of

welding machine is tested.

4.2. TROubLESHOOTINg

Power On light is not lit.

There is no power in the machine.

• Check mains fuses, replace blown fuses.
• Check mains cable and plug, replace defect parts.

The machine is not welding properly.

There are plenty of spatters during welding. Weld joint is porous or power supply is insufficient.

• Check welding settings and adjust if needed.
• Check gas flow and gas hose connection.
• Check that earth clamp is properly fastened and that earth cable has no defects. Change the

position if necessary and replace defect parts.

• Check welding torch cable and connector. Tighten the connection and replace defective

parts.

• Check the consumable parts of welding torch. Clean and replace defect parts.
• Check mains fuses, replace blown fuses.

Power source overheat indicator light is lit.

Power source is overheated.

• Check that there is enough free space behind the machine for cooling air circulation.
• Check cooling unit for water circulation, cleanliness of heat exchanger and air grate. Add

cooling liquid if necessary.

For further information and assistance, contact your nearest Kemppi service workshop.

Advertising